Menu

MPQ1000

Handheld Power Quality Analyzer

  • Auto CT identifies the current clamp that is connected to the analyzer as well as the range to which the CT is set
  • Configuration verification which identifies and notifies you if the product has been connected incorrectly
  • On-board data analysis which can compare results against canned or custom standards.  Create your own templates for internal your company standards
  • SD Card Support, USB Card Support, USB Communications as well as Ethernet connections making it versatile

The MPQ1000 handheld power quality analyzer has features which make it ideal for troubleshooting, compliance testing and energy audits.  Auto CT identification eliminates potential errors due to wrong CT range settings. The analyzer will automatically identify the CT and verify it is connected correctly. This means you can be confident you will have the correct data.

But the hardware is not all it’s about – behind the sturdy exterior is an intelligence that is focused on smart testing, with industry-leading software that enables you to minimize errors while testing, and quickly and easily analyze your results. For example, you can create your own company standard templates that can be stored and compared, as well as check your results against compliance standards.  This saves time, effort and costs, making your entire testing process more efficient.

The software automatically creates custom configurations based on the issue you are troubleshooting, whether it be equipment tripping out, transformer or motor issues, EN50160 analysis or general PQ analysis. This ensures the analyzer will capture the power quality phenomenon that causes those problems. You do not have to be a PQ expert to carry out a comprehensive analysis.
 

Megger PQ Firmware for MPQ Series PQ Analysers

Here you will find Firmware to be loaded into the MPQ1000 and MPQ2000 analysers.

The current update files MPQFirmwareUpdate20170920_A.zip and MPQFirmwareUpdate20170920_B.zip both contain the specific instructions for updating the MPQ1000 and specific instructions for updating the MPQ2000. 

WARNING: There are 2 release packages. Each one function only with its proper main board. Check the OS revision in the OS field of the HELP screen of the MPQ analyzer. (Press the HELP “?” key to view the HELP screen)

If the OS is 1.1.0.0 or lower, use MPQFirmwareUpate20170920_A.zip, otherwise use MPQFirmwareUpate20170920_B.zip. 

  • MPQFirmwareUpate20170920_A.zip only functions with older main board revisions.
  • MPQFirmwareUpdated20170920_B.zip functions only with new revision main boards.  

NOTE: If the wrong firmware version is installed text on the display will be orientated in the wrong direction. If this does happen simply install the other firmware package.

Download and extract the proper zip file to a clean (empty) thumb drive. 

This firmware adds the following functionality to both the MPQ1000 and MPQ2000. 

  • Adds Romanian and Czech language support.
  • Calibration fixes for ASCs.
  • Updates the Windows CE OS for operation with the new main board.

 

Firmware-Update-2017-02-24-(A)
Description (A):
OS, FW, CE updates for old hardware revision
OS File Size: 17.2 MB
OS File Date/Revision: 1.1.0.2
CE File Size: 272 KB
CE File Date/Revision: 1.1.0.7
FW File Size: 4.52 MB
FW File Date/Revision: 2017.07.27/1.255
Firmware-Update-2017-02-24-(A).zip
11.8 MB | 24/11/17
Firmware-Update-2017-09-20-(B)
Description (B):
OS, FW, CE updates for new hardware revision
OS File Size: 17.2 MB
OS File Date/Revision: 1.2.0.1 
CE File Size: 272 KB
CE File Date/Revision: 1.1.0.7
FW File Size: 4.52 MB
FW File Date/Revision: 2017.07.27/1.255
Firmware-Update-2017-09-20-(B).zip
11.8 MB | 24/11/17
Megger PQ PC Software for MPQ Series PQ Analyzers

Software Version: 2.2.0.4

Unzip the file and execute the Installer file MeggerPQ_ML_2.2.0.4.exe

The installer will over write any previous install and clean up any files no longer needed.

The files will be loaded to the Megger installation folder.

This software version adds the following functionality.

1.     Adds Czech language support

2.     Adds an EN50160 report to the standard report compliment.

For those that wish to validate the content of the installer file, there is an MD5 text file included which contains the hash code for the installer file.

The MD5 hash was created with the program fsum.exe from SlavaSoft Inc.   (http://www.slavasoft.com)

Beside your own MD5 calculator either the fsum.exe or HashCalc.exe programs from SlavaSoft can be used to verify the download integrity of the file.  Megger has no affiliation with SlavaSoft Inc. This information is only provided for your convenience.

Link MPQ Software Download for PC
File Name: File Name: MeggerPQ_English_1_0_2_0.zip Software Version: 1.0.2.0 Unzip the file and execute the Installer file MeggerPQ_English_1_0_2_0.exe At this time, if you already have an older version of the software installed you will have to run the file twice. Once to remove the old software and again to install the new. For those that wish to validate the content of the installer file. There is an MD5 text file included which contains the hash code for the installer file. The MD5 hash was created with the program fsum.exe from SlavaSoft Inc. (http://www.slavasoft.com) Beside your own MD5 calculator either the fsum.exe or HashCalc.exe programs from SlavaSoft can be used to verify the download integrity of the file. Megger has no affiliation with SlavaSoft Inc. This information is only provided for your convenience.
Megger-Muti-Language2-2-0-4-exe.zip
20.6 MB | 24/11/17
Link User guide - Megger power quality software
1.9 MB
MPQ-SWG-EN-V02.pdf
1.9 MB | 24/11/17