Total Demand Distortion (TDD)
Total Harmonic Distortion (THD) is a common method used to measure the level of waveform distortion.Total Harmonic Distortion (THD) measurements are an effective method of evaluating voltage distortion. However THD can be misleading when evaluating current distortion. THD is the summation of the harmonics presented as a percentage of the fundamental. For voltage THD this will be the summation of the voltage harmonics compared to the fundamental voltage. In a non-faulted condition voltage will always be present so a proper reference always exists.
Published: 11 April 2019
Download PDF
MPQ2000 Common Connections
An application note locoking at the common connections of the MPQ2000.
Published: 10 April 2019
Download PDF
MPQ2000 Monitoring a TT grounded system
Measuring the voltage between the ground and neutral provides an indication of the integrity of the ground connection. The poorer the connection (higher impedance), the higher the voltage between the neutral and ground conductors will be. During a fault, this level could rise over 50 V and become a serious hazard.
Published: 10 April 2019
Download PDF
CBEMA Curve
The MPQ can capture up to 1000 events. This number of events can be time consuming to review and analyze.The CBEMA / ITIC curve allows for quick analysis of dip (sags), swells and sub-cycle (transient) events.
Published: 10 April 2019
Download PDF
Rapid Voltage Change (RVC)
A rapid voltage change is a fast rise or fall of the RMS voltage. This can be caused by the switching on of a specific load or by a sudden change in source voltage. Sudden source voltage changes can occur in solar grids when the sun is obscured by clouds. Source voltage changes can also occur in wind farms when then wind speed decreases. Load switching can cause a rapid voltage change if the rating of the load is a significant fraction of the fault level of the supply voltage.
Published: 7 December 2018
Download PDF
Enabling Additional Channels
When creating a setup file a particular power wiring connection needs to be selected. This instructs the instrument on how to calculate the power and energy. When the power wiring connection is create the required input channels are automatically enabled.In some cases the operator may wish to enable additional channels for other measurements. This will not affect the power or energy measurements.
Published: 6 December 2018
Download PDF
Mains Signaling
Power-line communication (PLC) carries data on a conductor that is also used simultaneously for AC electric power transmission or electric power distribution to consumers. It is also known as power-line carrier, power-line digital subscriber line (PDSL), mains communication, power-line telecommunications, or power-line networking (PLN).
Published: 6 December 2018
Download PDF
Scheduled run - MPQ series of power quality analysers
The MPQ Series of Power Quality Analysers can be programmed to start and stop recording at specific times. This type of test is called a scheduled run.
Published: 6 November 2018
Download PDF
Solar Energy - Part 2 of 3: Programming a PQ Analyzer
When examining potential power quality issues associated with solar panels, your power quality analyzer should be programmed to examine a variety of different parameters outlined in this application note.
Published: 3 July 2018
Download PDF
Determining harmonic direction
Harmonics are caused by non-linear loads. Linear loads draw a linear current that follows the changing voltage of the AC waveform. Non-linear loads draw current pulses periodically, which creates distorted waveforms.
Published: 21 May 2018