Menu
Support
Technical library

Technical library

The Megger technical library provides access to a range of additional content and resources such as technical guides, application notes and more. Use the filters to browse specific content (e.g. application notes) or refine your search to a particular electrical application area. 

 

If you would like to see the content we have available on a particular subject or need to locate some software, simply enter a search below. Please note, you will need to create an account to access some resources.

Filter by application type:
    Showing item(s) 41 - 50 of 380 in total
Scanner Feature for the BITE2 and Power DB
If a scanner is used to scan a battery bar code the battery string name will be saved in the data file. A bar code can be created with a string name.  This is then scanned into the BITE2 receiver, using the bar code reader. When the data is transferred to Power DB the string will display the bar code, during the download.
Published: 6 November 2019
Download PDF
Testing Batteries with 2mm Access Ports
Batteries can present an arc hazard due to their exposed terminals (posts). If a non-insulated tool should fall across these terminals the resulting arc flash can injure people in the vicinity as well as damage equipment. This is why insulated tools should be used when working on battery strings. This is also why some batteries have caps covering their posts. These caps are removed during testing.
Published: 6 November 2019
Download PDF
NERC Testing with the BITE2
In 2007 FERC approved 83 NERC (North American Electric Reliability Council)   Reliability Standards, the first set of legally enforceable standards for the U.S. bulk power system. Compliance with approved NERC Reliability Standards is now mandatory and enforceable in the United States.
Published: 6 November 2019
Download PDF
Battery Ohmic Measurement AC or DC?
Ohmic measurements can be performed with AC or DC current. Which provides the most information about the battery? To answer this we first have to ask what the characteristics of a battery are.
Published: 6 November 2019
Download PDF
Ground Fault Protection Testing per NEC 230.95(C) of Low Voltage Circuit Breakers
This application note will cover why primary injection is specified per NFPA70/NEC standards, the basics of Ground Fault (GF) testing, and the challenges associated with testing Low Voltage (LV) circuit breakers using primary injection such as cable length, power sources, breaker configurations, and Current Transformer (CT) polarity.
Published: 6 November 2019
Download PDF
MRCT
Software download files for MRCT
Published: 4 November 2019
Download
MeggerBook Cable Brochure
Your complete software solution for managing, analysing and logging measurement data and cable data.
Published: 24 October 2019
Download PDF
Updating BITE3 Firmware with Power DB LITE
This procedure will guide you through updating the firmware in the BITE3 using the Power DB LITE software. It is recommended that you first download the latest firmware from the Megger web site.
Published: 18 October 2019
Download PDF
Guide to Low Voltage Motor Testing
Guide to Low Voltage Motor Testing
Published: 3 October 2019
Download PDF
IEEE guide for dielectric frequency response test advancements in industry
The  Institute  of  Electrical  and  Electronic  Engineers  (IEEE)  Standards  Association recently approved the publication of IEEE Std. C57.161–2018, Guide for Dielectric Frequency Response Test. The work was developed within the IEEE Transformers Committee and the Dielectrics Subcommittee. The industry needed a document to better understand the field application of a non-intrusive and non-destructive method to assess the condition of oil-paper insulation in power and distribution transformers.
Published: 1 October 2019
Download PDF Read full article
  • <
  • 1
  • 2
  • 3
  • 4
  • 5
  • ...
  • >
  • Showing item(s) 41 - 50 of 380 in total