SVERKER900 - Testing-ROCOF-protection
Rate Of Change Of Frequency (ROCOF) protection is used in distributed or embedded generation schemes, where a local generator is connected directly to the distribution network, as specified in national standards such as Ansi 81R or G59/3
Published: 15 May 2019
Download PDF
SVERKER900 - Testing ABB Trip Circuit Supervision relay
Check trip on relay with ABB supervision relay
Published: 15 May 2019
Download PDF
SVERKER900 - Testing impedance based protection
The impedance measurement schemes are widely used for protection of different assets within electric power systems. Relay protection devices utilizing such schemes are benefiting from continuous monitoring of both voltage and current quantities within the protected circuit and the calculated impedance value is employed to determine whether the circuit is operating in a normal condition or not.
Published: 15 May 2019
Download PDF
SVERKER900 - Testing negative sequence overcurrent protection
Unbalance phase currents in a power system that exceed the allowable normal operation limit can indicate abnormal condition or even existence of fault(s) in the system. The operating principal unbalance over current protection is normally based on measurement of negative sequence component of unbalance phase currents. Similar to phase over current protection, normally a pick up (start) threshold and a definite time delay for operation can be set.
Published: 15 May 2019
Download PDF
SVERKER900 Demo Testing
To be used as demonstration/course material
Published: 15 May 2019
Download PDF
SVERKER900 - Testing directional earth fault
Directional earth fault protection are commonly used to protect long outgoing feeders from tripping because of fault on other outgoing lines.
Published: 15 May 2019
Download PDF
PowerDB Brochure
A brochure explaining our PowerDB software. This intuitive and robust software interface simplifies the acquisition and management of your test data, giving you control of your Asset Management Process.
Published: 10 May 2019
Download PDF
Dangerous Voltage: Staying Safe Using High Voltage Test Equipment
Electrical test instrumentation often must operate at medium…or even high…voltages. But even “low” voltage can kill you. What are the guidelines that an operator should consider when selecting and working with instrument test voltages? 
Published: 9 May 2019
Download PDF
MLR10
Software download files for MLR10
Published: 16 April 2019
Download
DFR: A New IEEE Guide for Field Test on Power and Distribution Transformers
The following article is a brief summary of the well-developed IEEE C.57.161-2018 “Guide for Dielectric Frequency Response Test”.  It thoroughly discusses the components and procedures of the guide, and the theories and history behind it. 